Recanalization with Wingspan Stent for Acute Middle Cerebral Artery Occlusion in Failure or Contraindication to Intravenous Thrombolysis: A Feasibility Study [INTERVENTIONAL]



Recanalization with Wingspan Stent for Acute Middle Cerebral Artery Occlusion in Failure or Contraindication to Intravenous Thrombolysis: A Feasibility Study [INTERVENTIONAL

  1. S.M. Sung,
  2. T.H. Lee,
  3. H.J. Cho,
  4. Y.L. Sol,
  5. K.H. Park,
  6. D.S. Jung and
  7. C.W. Kim
: BACKGROUND AND PURPOSE:

Recanalization with the Wingspan stent, which can be deployed rapidly and safely, is an option for treating acute ischemic stroke when intravenous thrombolysis has failed or is contraindicated. This study was performed to evaluate feasibility, efficacy, and safety of recanalization for acute middle cerebral artery occlusion using the Wingspan stent.

MATERIALS AND METHODS:

We collected 10 patients with acute MCA occlusion in whom recanalization was not achieved with a standard intravenous thrombolysis, or who were ineligible for intravenous thrombolysis, or who presented after 3 hours of symptom onset and in whom the stent placement could be completed within 8 hours from symptom onset. We analyzed angiographic and clinical results.

RESULTS:

Successful recanalization with the Wingspan stent was achieved in all patients. The mean NIHSS score on admission was 12.7 points (range 4–21). The occlusion sites were located in the 1st segment (n = 7; 2 left, 5 right) and 2nd segment (n = 3, all right) of the MCA. The mean time interval from stroke symptom onset to stent placement was 344.8 ± 76.3 minutes. No intracranial hemorrhage, vessel perforations, or dissections occurred in any patient. Nine patients improved on the NIHSS at 7 days. One patient did not have a change in the NIHSS score, even though the occluded artery was completely recanalized. At 7 days, the NIHSS score of all patients was 4.4 ± 4.7 (median 4, range 0–13). At discharge, an mRS of ≤3 was achieved in all patients and an mRS of ≤2 was achieved in 7 patients (70%).

CONCLUSIONS:

This small case series demonstrates the feasibility of using the Wingspan stent safely and effectively for MCA occlusions when standard treatments are ineffective or not available.

http://www.ajnr.org/content/early/2012/02/09/ajnr.A2996.abstract


Read More Add your Comment 0 comments


Incomplete mechanical recanalization of middle cerebral artery occlusions facilitates endogenous recanalization within 5 h



Incomplete mechanical recanalization of middle cerebral artery occlusions facilitates endogenous recanalization within 5 h
Background and purpose

Successful revascularization can often improve functional outcome after large intracranial arterial occlusions. However, incomplete or unsuccessful recanalization is often the end result after attempted mechanical thrombectomy. A study was undertaken to determine whether partial recanalization of proximal isolated middle cerebral artery (MCA) occlusions facilitates endogenous thrombolysis and spontaneous recanalization.

Methods

We retrospectively analyzed consecutive patients with acute ischemic stroke undergoing mechanical thrombectomy using the Merci Retriever System for occlusions involving any portion of the M1 segment of the MCA. Only those patients with a residual obstruction of the proximal MCA segments were included. The rates of facilitated endogenous recanalization (FER5) by imaging within the 5 h following intervention were compared in patients with partial proximal recanalization and those in whom recanalization was unsuccessful.

Results

Forty-two patients were included in the analysis. Twenty-six patients had good recanalization of the proximal aspect of the target lesion with an arterial occlusive lesion score of 2 or 3 but a residual partial or total occlusion of the MCA, while 16 patients failed to recanalize any portion of the target occlusion. Twelve patients (46%) in the first group and only one (5.9%) in the second group had facilitated endogenous recanalization on interval imaging 5 h after intervention (OR 12.9, 95% CI 1.5 to 112.2). Nine patients with proximal recanalization had good clinical outcomes at discharge (mRS ≤2) compared with none without recanalization (p=0.01), but FER did not have a relationship with clinical outcome.

Conclusions

Despite initially incomplete proximal mechanical thrombectomy, nearly half of all patients with residual M1 occlusions will undergo further endogenous recanalization within the subsequent 5 h.

http://jnis.bmj.com/content/early/2012/02/06/neurintsurg-2011-010207.short


Read More Add your Comment 0 comments


Routine pre-procedure laboratory testing for patients undergoing outpatient cerebral angiography is not indicated



Background

Cerebral angiography is a routine low-risk procedure. Laboratory testing is performed in almost all patients. Some testing may be warranted in selected patients but can also result in delays in performing the procedure.

Purpose

To determine if routine pre-procedure testing for outpatient cerebral angiography is necessary.

Methods

447 patients who underwent outpatient cerebral angiography were reviewed. The tests were evaluated for any abnormality, correlation of the abnormality with underlying diseases and for any impact that these tests may have on the safety of the procedure. Only tests performed at our institution were analyzed. All instances of any hospital/physician visit related to the procedure were recorded.

Results

A low hemoglobin, hematocrit and platelet count was seen in 3.5%, 1.8% and 0.1% of patients, respectively. These were marginally outside the reference range and not sufficiently abnormal to indicate underlying disease or to affect the procedure. An elevated prothrombin time/international normalized ratio was seen in 4.5% of patients and this was associated with warfarin use (p<0.0001). About 15% of the patients had a disturbance in renal function. An elevated creatinine was associated with diabetes (OR 3.2, 95% CI 1.8 to 5.7, p=0.0001) and hypertension (OR 4.4, 95% CI 2.1 to 9.2, p<0.0001). Cerebral angiography was performed on these patients with appropriate renal protective measures and no cases of acute renal failure secondary to contrast administration were documented.

Conclusion

The incidence of abnormal testing in patients undergoing outpatient cerebral angiography is very low. These results and evidence in the literature suggest that the majority of patients undergoing cerebral angiography do not require any pre-procedure testing. Assessment of renal function using the estimated glomerular filtration rate in high-risk patients only is, however, warranted.

http://jnis.bmj.com/content/early/2012/02/08/neurintsurg-2011-010200.short


Read More Add your Comment 0 comments


Interpretation Errors in CT Angiography of the Head and Neck and the Benefit of Double Reading



Read the imaging correctly folks.... aneurysms are the ones missed most...

http://www.ajnr.org/content/32/11/2132.abstract

Interpretation Errors in CT Angiography of the Head and Neck and the Benefit of Double Reading

Sean P. Symons, MPH, MD, FRCPC, Division of Neuroradiology, Department of Medical Imaging, 2075 Bayview Ave, AG31D, Toronto, ON, Canada, M4N 3M5; e-mail: sean.symons@sunnybrook.ca

Abstract

BACKGROUND AND PURPOSE: CTA provides high-resolution imaging of the head and neck vasculature but also of the soft tissues and bones. This results in a large volume of information to be interpreted. This study examines interpretation errors with head and neck CTAs and assesses whether double reading reduces miss rates.
MATERIALS AND METHODS: Consecutive CTAs of the neck and intracranial circulation were retrospectively identified and reviewed for vascular and nonvascular findings by a consensus of 2 neuroradiologists. The results were compared with the official report. Significant discrepancies were considered those that would have influenced follow-up or management.
RESULTS: We reviewed 503 studies; 144 were originally reported by a staff neuroradiologist alone, 209 by staff and diagnostic radiology resident, and 150 by staff and neuroradiology fellow. Twenty-six significant discrepancies were discovered in 20 studies, corresponding to 4.0% of studies with at least 1 miss, and an overall miss rate per study of 5.2%. There was at least 1 miss in 6.3% of studies interpreted by a staff neuroradiologist alone, 3.3% by staff and resident, and 2.7% by staff and fellow. The miss rate differences were not statistically significant. The most common misses were small aneurysms (50% of misses).
CONCLUSIONS: CTA neck and head datasets are now large, and there is a potential for missed findings. Significant discrepancies can occur with a low but not insignificant rate. Arterial pathology accounted for most discrepancies. This study emphasizes the need for careful systematic scrutiny for both vascular and nonvascular pathology regardless of indication. Double reading reduces error rates.


Read More Add your Comment 0 comments


cPAX Aneurysm Treatment System from NeuroVasx



cPAX is a polymeric strand delivered into the aneurysm using a technique similar to currently available platinum coil technologies.  cPAX, because of its soft polymeric material, is designed to achieve more complete filling of the aneurysm with the probable benefit of greater long term stability.  A significant feature of cPAX in comparison to currently available technologies is that it offers the physician the ability to detach the device at any point versus a fixed detachment zone common in platinum coils.  The polymeric material also allows for non-invasive CT and MRI scans with little or no artifact for more accurate patient follow-up assessment.

ade34343 NeuroVasxs cPAX Aneurysm Treatment Gets Limited FDA Approval


Read More Add your Comment 0 comments


Monitoring Embolized Brain Aneurysms Without radiation or contrast



researchers from the University of British Columbia have discovered an interesting property of the platinum embolism implant – it can act as a fairly accurate sensor and antenna. The reason is simply that the implant’s coiled shape causes its material properties, namely its resonance frequency, to vary depending on the blood flow through it. A simple handheld RF reader is all that would be required to monitor the status of the embolization-coil sensor.20gdpad7 Researchers Devise Method of Monitoring Embolized Brain Aneurysms Without Making Patients Turn Nuclearxiwo5qlu Researchers Devise Method of Monitoring Embolized Brain Aneurysms Without Making Patients Turn Nuclear

Biosens Bioelectron. 2011 Dec 15;30(1):300-5. Epub 2011 Oct 1.

Radio aneurysm coils for noninvasive detection of cerebral embolization failures: A preliminary study.

Source

Department of Electrical & Computer Engineering, University of British Columbia, 2332 Main Mall, Vancouver, BC, V6T 1Z4 Canada.

Abstract

The rupture of a cerebral aneurysm is the most common cause of subarachnoid hemorrhage. Endovascular embolization of the aneurysms by implantation of Guglielmi detachable coils (GDC) has become a major treatment approach in the prevention of a rupture. Implantation of the coils induces formation of tissues over the coils, embolizing the aneurysm. However, blood entry into the coiled aneurysm often occurs due to failures in the embolization process. Current diagnostic methods used for aneurysms, such as X-ray angiography and computer tomography, are ineffective for continuous monitoring of the disease and require extremely expensive equipment. Here we present a novel technique for wireless monitoring of cerebral aneurysms using implanted embolization coils as radiofrequency resonant sensors that detect the blood entry. The experiments show that commonly used embolization coils could be utilized as electrical inductors or antennas. As the blood flows into a coil-implanted aneurysm, parasitic capacitance of the coil is modified because of the difference in permittivity between the blood and the tissues grown around the coil, resulting in a change in the coil's resonant frequency. The resonances of platinum GDC-like coils embedded in aneurysm models are detected to show average responses of 224-819MHz/ml to saline injected into the models. This preliminary demonstration indicates a new possibility in the use of implanted GDC as a wireless sensor for embolization failures, the first step toward realizing long-term, noninvasive, and cost-effective remote monitoring of cerebral aneurysms treated with coil embolization.

http://www.ncbi.nlm.nih.gov/pubmed/22014417


Read More Add your Comment 0 comments


Nfocus Luna Aneurysm Embolization System



The Luna AES treats brain aneurysms by blocking (embolizing) blood flow while providing a scaffold to encourage tissue growth across an aneurysm opening and create a plug. The Luna uses a self-expandable, multi-layer oval implant made from Nitinol, a nickel-titanium alloy. The properties of the device allow it to easily compress within a conventional catheter, and then rapidly and easily open to full size once deployed within an aneurysm.

gq3gedrt Nfocus Luna Aneurysm Embolization System Gets EU OK


 


Read More Add your Comment 0 comments


The Safety of Intravenous Thrombolysis for Ischemic Stroke in Patients With ...



 
 

Sent to you by subbu via Google Reader:

 
 

via Stroke ASAP by Edwards, N. J., Kamel, H., Josephson, S. A. on 12/8/11

Background and Purpose—

Unruptured cerebral aneurysms are currently considered a contraindication to intravenous tissue-type plasminogen activator for acute ischemic stroke. This is due to a theoretical increase in the risk of hemorrhage from aneurysm rupture, although it is unknown whether this risk is a significant one. We sought to determine the safety of intravenous tissue-type plasminogen activator administration in a cohort of patients with pre-existing aneurysms.

Methods—

We reviewed the medical records of patients treated for acute ischemic stroke with intravenous tissue-type plasminogen activator during an 11-year period at 2 academic medical centers. We identified a subset of patients with unruptured cerebral aneurysms present on prethrombolysis vascular imaging. Our outcomes of interest were any intracranial hemorrhage, symptomatic intracranial hemorrhage, and subarachnoid hemorrhage. Fisher exact test was used to compare the rates of hemorrhage among patients with and without aneurysms.

Results—

We identified 236 eligible patients, of whom 22 had unruptured cerebral aneurysms. The rate of intracranial hemorrhage among patients with aneurysms (14%; 95% CI, 3%–35%) did not significantly differ from the rate among patients without aneurysms (19%; 95% CI, 14%–25%). None of the patients with aneurysms developed symptomatic intracranial hemorrhage (0%; 95% CI, 0%–15%) compared with 10 of 214 patients without aneurysms (5%; 95% CI, 2%–8%). Similar proportions of patients developed subarachnoid hemorrhage (5%; 95% CI, 0%–23% versus 6%; 95% CI, 3%–10%).

Conclusions—

Our findings suggest that intravenous tissue-type plasminogen activator for acute ischemic stroke is safe to administer in patients with pre-existing cerebral aneurysms because the risk of aneurysm rupture and symptomatic intracranial hemorrhage is low.


 
 

Things you can do from here:

 
 


Read More Add your Comment 0 comments


Dural venous sinus angioplasty and stenting for the treatment of idiopathic intracranial hypertension



Dural venous sinus angioplasty and stenting for the treatment of idiopathic intracranial hypertension

J NeuroIntervent Surg doi:10.1136/neurintsurg-2011-010156

Background

Lumboperitoneal shunt (LPS), ventriculoperitoneal shunt (VPS) and optic nerve sheath fenestration (ONSF) are accepted surgical therapies for medically refractory idiopathic intracranial hypertension (IIH). In the subset of patients with IIH and venous sinus stenosis, dural venous sinus stenting has emerged as an alternative surgical approach.

Methods

All cases of dural stents for IIH at our institution were retrospectively reviewed. Eligibility criteria included medically refractory IIH with documented papilledema and dural venous sinus stenosis of the dominant venous outflow system (gradient ≥10 mm Hg).

Results

Fifteen cases (all women) of mean age 34 years were identified. All had failed medical therapy and six had failed surgical intervention. Technical success was achieved in all patients without major periprocedural complications. The mean preprocedural gradient across the venous stenosis was reduced from 24 mm Hg before the procedure to 4 mm Hg after the procedure. Headache resolved or improved in 10 patients. Papilledema resolved in all patients and visual acuity stabilized or improved in 14 patients. There were no instances of restenosis among the 14 patients with follow-up imaging.

Conclusion

In this small case series, dural sinus stenting for IIH was performed safely with a high degree of technical success and with excellent clinical outcomes. These results suggest that angioplasty and stenting for the treatment of medically refractory IIH in patients with dural sinus stenosis warrants further investigation as an alternative to LPS, VPS and ONSF.


Read More Add your Comment 0 comments


Mechanical thrombectomy as first-line treatment for venous sinus thrombosis: technical considerations and preliminary results using the AngioJet devic



Background

Cerebral venous sinus thrombosis (CVT) is an uncommon cause of stroke that is usually treated medically with intravenous heparin therapy followed by long-term anticoagulation therapy. A series of patients with CVT who underwent rheolytic thrombectomy with the AngioJet as a first-line adjunctive treatment in addition to standard anticoagulation therapy is presented.

Methods

Prospectively maintained endovascular databases at two institutions were retrospectively reviewed. The available clinical and imaging data were compiled at each institution and combined for analysis.

Results

Over 18 months, 13 patients (seven women and six men; age range 17–73 years, median age 45 years) with CVT were treated with rheolytic thrombectomy. Immediate (partial or complete) recanalization of the thrombosed intracranial sinuses was achieved in all patients. At a median radiographic follow-up of 7 months there was continued patency of all recanalized sinuses. Clinical follow-up was available on nine patients: modified Rankin score of 0 in four patients, 1 in three patients and 6 in two patients.

Conclusion

This series demonstrates the feasibility of performing mechanical thrombectomy as a first-line treatment for acute CVT. This technique facilitates the prompt restoration of intracranial venous outflow, which may result in rapid neurological and symptomatic improvement.


Read More Add your Comment 0 comments


 

© 2010 Science of Neurointervention All Rights Reserved